we need plans for a permit. Wein a high-rise condo and are removing some partial walls to remodel a kitchen, add a French door to a study and reposition the doors for a closet so the doors open into a hallway. These projects have all been done in the units in the same towers as ours
Here is a response form the village:
All codes referenced are to the 2006 International Residential Code, 2005 National Electrical Code (NFPA 70), Illinois Plumbing Code, 2012 International Energy Conservation Code, Referenced Standards and local code amendments.
1. Please provide an accurate cost of construction. Include all fixed-in-place appliances (dishwasher, cook top, built in microwave, etc.) cabinets, counter tops, flooring, tile, electrical, plumbing, mechanical material and labor. All owner supplied materials and plumbing fixtures shall be included.
2. Please add the Village of Wilmette adopted building codes to the cover page or each page of the plans.
3. Number each page 1/4, 2/4, 3/4….
4. Please provide accurate, dimensioned floor plans showing locations of all walls, cabinets, plumbing and electrical devices/fixtures.
5. This structure is a 2A construction type, requiring metal suds for all wall/floor/ceiling construction. No combustible material permitted.
6. Kitchen counter outlets shall be shown on the plans in the correct location(s) in accordance with the 2005 NEC, Article 210.52 (C). This would include the 24” maximum distance from the sink and range edges and on the end of the peninsula.
7. Electrical service shall be code compliant. No sub panels are permitted. No tandem breakers are permitted. 100 ampere services are limited to 20 spaces, 200 ampere services are limited to 42 spaces. All electrical panels shall have a main breaker. An electrical service upgrade may be necessary.
8. All non-compliant electrical and plumbing exposed during this remodel will require these systems to be upgraded in accordance with the currently adopted codes.
9. All closets shall have switch controlled light, no pull chains are permitted.
10. Smoke detectors are required throughout, if not exiting and complaint. These shall be hardwired and interconnected (wireless OK). Please indicate the proposed locations on the plans.
Hi!
We create 3D visualization of Interior and Exterior architecture scenes. Visualization of interiors and exteriors before and after project. Please check some our portfolio from our profile link..
Our expertise includes Building Architecture.
Please contact me to discuss more regarding this project.
Thanks
Hello,
I review your project description. I am interested in doing this job.
We are team of architect and interior designer calculating 5+ years .
We guarantee 100% dedication to your project. We will try to give best of our effort to complete your project as per your expectation.
Please have a look at my past works .
https://www.freelancer.in/u/Aamruta09
Looking forward to hearing from you.
Thank and Regards
Amruta
Hi there! We are confident that we can fulfill your requirement- Sheridan Road highrise condo in Wilmette, IL. We are a team of architects, interior designers and 3D artists.
Our Services:
--Architectural and interior design including Residential and commercial.
-- Photorealistic 3D Renders
--High quality 3D Modelling
Chat to discuss.
I do hope we'll be able to speak soon
We will be a glad to work with you.
Regards,
SM Studio
We are a team of professionals trained under Autodesk and hence we can cover your all requirements perfectly, meanwhile following all the building codes and guarantee to submit them before the time frame you provide us.